The 800 series MICROLITER
syringes are a development of the 700 series syringes
and are liguid tight.
The plungers are equipped with a removable metal handle which
prevents heat transfer and the fine plunger from bending.
The handle is assembled with a special stop that prevents
the plunger from blowing out. If the glass barrel becomes
damaged, the barrel can be easily replaced in the lab. The
accuracy is ±1% of the normal volume.
Typical applications are:
1) Sample injections in HPLC valves
2) Manual sample injections in GC
3) Sample collection from deep containers |
5無 -
250無
- For use with liquids
- Removable needles (RN), or cemented needles (N)
- Reinforced plungers
- Barrel/plunger assemblies are replaceable
- Plunger stop prevents plunger blowout
|
|
N Syringes
(Cemented Needle)
|
Volume: |
5
無 |
10
無 |
25
無 |
50
無 |
100
無 |
250
無 |
Model: |
85 |
801 |
802 |
805 |
810 |
825 |
Gauge**: |
26s |
26s |
22s |
22s |
22s |
22s |
| |
|
|
|
|
|
N
(Cemented Needle) |
Point
Style 2
(Bevelled for septum penetration) |

Needle: 51mm |
|
|
|
|
|
|
|
RN Syringes (Removable Needle)
|
|
| |
| |
| |
RN
(Removable Needle) |
Point
Style 2
(Bevelled for septum penetration) |

Needle: 51mm |
|
|
|
|
|
|
RN
(Needle not included)  |
|
|
|
|
|
|
|
|
|
Accessories
|
|
| |
| |
| |
Reproducibility
(Chaney) Adapter
(Syringe not included) |
 |
|
|
|
|
|
|
| |
| |
Replacement Parts: |
| |
Volume: |
5
無 |
10
無 |
25
無 |
50
無 |
100
無 |
250
無 |
| Description |
Model: |
85 |
801 |
802 |
805 |
810 |
825 |
| 1.
Barrel/Plunger Assembly N |
|
|
|
|
|
|
| Barrel/Plunger
Assembly SN1 |
|
|
|
|
|
|
| Barrel/Plunger
Assembly RN |
|
|
|
|
|
|
Barrel/Plunger
Assembly RN Syringe2 |
|
|
|
|
|
|
| 2.
Holder Assembly |
|
|
|
|
|
|
| 3.
RN Nut |
|
|
|
|
|
|
| |
| 1)
Specify needle gauge, length, point
style and whether electro-tapered |
| 2)
Needle not included |
|
|
|
|
|
|
| |
Replacement Needles
|
| |
Volume: |
5
無 |
10
無 |
25
無 |
50
無 |
100
無 |
250
無 |
| Description |
Model: |
85 |
801 |
802 |
805 |
810 |
825 |
Standard
RN Needles
6 Pack | 51mm | Point Style 2 |
|
|
|
|
|
|
| |
Technical Specifications For Standard
Replacement Needles
|
Syringe
Capacity: |
5
無 |
10
無 |
25
無 |
50
無 |
100
無 |
250
無 |
Model: |
85 |
801 |
802 |
805 |
810 |
825 |
| Needle
Length (mm) |
51 |
51 |
51 |
|
51 |
51 |
| Needle
Gauge |
26s |
26s |
22s |
22s |
22s |
22s |
| Needle
Outer Diameter (mm) |
0.47 |
0.47 |
0.72 |
0.72 |
0.72 |
0.72 |
| Needle
Inner Diameter (mm) |
0.13 |
0.13 |
0.15 |
0.15 |
0.15 |
0.15 |
| Needle
Point Style |
2 |
2 |
2 |
2 |
2 |
2 |
| Electro-tapered |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
| Dead
Volume in Needle (µL) |
0.68 |
0.68 |
0.90 |
0.90 |
0.90 |
0.90 |
| Scale
Length (mm) |
54 |
54 |
60 |
60 |
60 |
60 |
| Test
Pressure (MPa) |
0.6 |
0.6 |
0.6 |
0.6 |
0.6 |
0.6 |
| |
|
|
| |
| Select the
relevant part number to enquire for details and availability,
or phone +44(0)1227 265333. |
| |
|
|
|
|