OPTI-PAK CAPILLARY TRAP CARTRIDGES
With bed volumes as low as a quarter
of a microliter, OPTI -PAK
trap cartridges are an elegant means of introducing
a low-volume trapping bed into your flow path.
A patented auto-adjusting design allows
OPTI-PAK
to be installed into any typical 10-32 port with absolutely
no dead volume. You can install OPTI-PAK
directly into the outlet port of any common injection
or switching valve, or straight into a detector inlet
port, without the need for additional connecting tubing
or fittings.
Install an OPTI-PAK
into the outlet of a switching valve to facilitate the
trapping, desalting and pre-concentration of an analyte
mixture, or add a second trap downstream in the loop
of an injection valve, and selectively elute analytes
from the first trap onto the se cond,
where they can be easily eluted onto your LC/MS.
OPTI-PAK is available in several low-volume
configurations, packed with a variety of large-particle
silica and polymeric phases.
OPTI-PAK
installs directly into 10-32 injection ports,
and automatically adjusts for ZDV connection,
allowing you to keep volume to a minimum.
Each OPTI-PAK
Trap Cartridge Kit Includes:
| |
|
| |
- 5 OPTI-PAK Holders
- 5 Trap Cartridges
- 1 Installation Tool
|
| |
|
|
|
OPTI-PAK TRAP CARTRIDGE
KIT
(5 Holder and Cartridges, 1 Installation Tool) |
| Build your OPTI-PAK
part number by adding the "bed code" for the
empty bed volume/dimension suitable for your application
to the "phase code" for the chemistry you need.
Pick any combination of dimension and any chemistry. Completed
part numbers take the form "10-02862-TA" (this
example would correspond to an OPTI-PAK
5-pack of cartridges with a 0.25µL bed volume and
C18 packing.) |
| Bed
volume/dimension |
BUILD PART NO. HERE |
Phase |
Bed
code |
Phase
code |
| 0.12µL |
10-03328- |
TA |
C18 |
| 0.25 µL |
10-03324- |
TB |
C18/AQ |
| 0.50 µL |
10-03317- |
TC |
C8 |
| 1.0 µL |
10-03225- |
TD |
C4 |
| 2.0 µL |
10-03229- |
TE |
SCX |
| 5.0 µL |
10-03233- |
TF |
SAX |
|
TG |
DVB |
| BED SELECTION GUIDE |
|
Use these guidelines to select an optimal
bed for your application. Please note, however, that
they are just guidelines, and not strict limits. |
| Sample Capacity |
Sample Volume |
Load Rate (Optimal) |
Suggested Bed Volume |
| 0.5 µg |
0.025-25 µL |
1.25-5 µL/min |
0.12 µL |
| 1 µg |
0.05 - 50 µL |
2.5 - 10 µL/min |
0.25
µL |
| 2 µg |
0.1 - 100 µL |
5 - 20 µL/min |
0.5
µL |
| 4 µg |
0.2 - 200 µL |
10 - 40 µL/min |
1.0
µL |
| 8µg |
0.4 - 400 µL |
20 - 80 µL/min |
2.0 µL |
| 20µg |
1.0 - 1000 µL |
50 - 200 µL/min |
5.0 µL |
| OPTI-PAK
TUBE SETS |
| Part
number |
Description |
| 10-20-02875 |
Tube Set, for OPTI-PAK
Trap Cartridges (Rheodyne Injection Valve) |
|
|
|
|
|
|
|
|
Jaytee Biosciences Ltd, 171 - 173, John Wilson
Business Park, Whitstable, Kent CT5 3RB
Tel: +44 (0) 1227 265333 Fax: +44 (0) 1227 265331 |
| © 2008 | Company
Info
Last updated
February 20, 2008 | This page generated on May 12, 2008 at 12:08:05 GMT

|