Showing 1361–1380 of 1399 results

  • £62.00
    AC-013242-CG

    Silica LC Guard Column (Cartridge). Porosity: 300Å, Length:...

    L3 (Stainless Steel Hardware). Length: 20mm, I.D.: 4.6mm, pH range: 1-10 Guard Cartridge

    Silica Phase 
    Alternative NameSilica
    Functional Group-OH
    USP DescriptionPorous silica particles - 5 to 10 µm in diameter
    ApplicationNon-polar and moderately polar organic compounds.
    Normal PhaseYes
    Reverse PhaseNo
    Ion ExchangeNo
    HILICYes
    Typical Efficency:75000 plates/m
    pH Range1-10

  • £51.00
    AC-013211-CG

    Silica LC Guard Column (Cartridge). Porosity:120Å, Length: ...

    L3 (Stainless Steel Hardware). Length: 20mm, I.D.: 2.1mm, pH range: 1-10 Guard Cartridge

    Silica Phase 
    Alternative NameSilica
    Functional Group-OH
    USP DescriptionPorous silica particles - 5 to 10 µm in diameter
    ApplicationNon-polar and moderately polar organic compounds.
    Normal PhaseYes
    Reverse PhaseNo
    Ion ExchangeNo
    HILICYes
    Typical Efficency:75000 plates/m
    pH Range1-10

  • £51.00
    AC-013221-CG

    Silica LC Guard Column (Cartridge). Porosity:120Å, Length: ...

    L3 (Stainless Steel Hardware). Length: 20mm, I.D.: 3.0mm, pH range: 1-10 Guard Cartridge

    Silica Phase 
    Alternative NameSilica
    Functional Group-OH
    USP DescriptionPorous silica particles - 5 to 10 µm in diameter
    ApplicationNon-polar and moderately polar organic compounds.
    Normal PhaseYes
    Reverse PhaseNo
    Ion ExchangeNo
    HILICYes
    Typical Efficency:75000 plates/m
    pH Range1-10

  • £51.00
    AC-013231-CG

    Silica LC Guard Column (Cartridge). Porosity:120Å, Length: ...

    L3 (Stainless Steel Hardware). Length: 20mm, I.D.: 4.0mm, pH range: 1-10 Guard Cartridge

    Silica Phase 
    Alternative NameSilica
    Functional Group-OH
    USP DescriptionPorous silica particles - 5 to 10 µm in diameter
    ApplicationNon-polar and moderately polar organic compounds.
    Normal PhaseYes
    Reverse PhaseNo
    Ion ExchangeNo
    HILICYes
    Typical Efficency:75000 plates/m
    pH Range1-10

  • £51.00
    AC-013241-CG

    Silica LC Guard Column (Cartridge). Porosity:120Å, Length: ...

    L3 (Stainless Steel Hardware). Length: 20mm, I.D.: 4.6mm, pH range: 1-10 Guard Cartridge

    Silica Phase 
    Alternative NameSilica
    Functional Group-OH
    USP DescriptionPorous silica particles - 5 to 10 µm in diameter
    ApplicationNon-polar and moderately polar organic compounds.
    Normal PhaseYes
    Reverse PhaseNo
    Ion ExchangeNo
    HILICYes
    Typical Efficency:75000 plates/m
    pH Range1-10

  • £650.00
    SOL-4775

    Solaris[PRO] Buffer Sterilisation Pack (1 litre b...

    Protects your HPLC

    HPLC Instrumentation are easily adversely affected by bacteria, fungi and algae. By removing the threat of contaminated buffer sitting in-line, the SOLARIS[PRO] keeps your system well conditioned, thus avoiding expensive downtime and engineer call-outs.

    Toxic chemicals no longer required

    SOLARIS[PRO] supersedes the requirement for algae inhibitors, such as Sodium Azide, which affect chromatography.

    Sealed environment

    SOLARIS[PRO] sterilises the solvent after the bottle is filled. By utilising a 0.2 μm air intake filter, biological pathogens cannot form. In addition, contamination with particles from the laboratory environment (e.g. dust) is also prevented.

    Savings: Time and cost

    Solaris looks after itself – by having the lamp continuously switched on, man hours are considerably reduced and process efficiency maximised; no wasted solvent, no solvent disposal, no down time while new buffer is created, no associated buffer / preservative costs.

    Easy to handle

    • The system comes ready to use and can be mounted on all 2L-5L solvent bottles with a GL-45 thread.
    • Easy to install and to replace.
    • Cleaning: Simply rinse with deionised water.
    • Includes everything to get started – UV lamp, extraction tool and universal power supply.
  • £650.00
    SOL-4774

    Solaris[PRO] Buffer Sterilisation Pack (2-5 litre...

    Protects your HPLC

    HPLC Instrumentation are easily adversely affected by bacteria, fungi and algae. By removing the threat of contaminated buffer sitting in-line, the SOLARIS[PRO] keeps your system well conditioned, thus avoiding expensive downtime and engineer call-outs.

    Toxic chemicals no longer required

    SOLARIS[PRO] supersedes the requirement for algae inhibitors, such as Sodium Azide, which affect chromatography.

    Sealed environment

    SOLARIS[PRO] sterilises the solvent after the bottle is filled. By utilising a 0.2 μm air intake filter, biological pathogens cannot form. In addition, contamination with particles from the laboratory environment (e.g. dust) is also prevented.

    Savings: Time and cost

    Solaris looks after itself – by having the lamp continuously switched on, man hours are considerably reduced and process efficiency maximised; no wasted solvent, no solvent disposal, no down time while new buffer is created, no associated buffer / preservative costs.

    Easy to handle

    • The system comes ready to use and can be mounted on all 2 litre -5 litre solvent bottles with a GL-45 thread.
    • Easy to install and to replace.
    • Cleaning: Simply rinse with deionised water.
    • Includes everything to get started – UV lamp, extraction tool and universal power supply.
  • £45.00
    SOL-4691

    Solaris[PRO] Solvent Extraction Accessory

    Prevent contamination

    This accessory builds on the benefits of securing your solvent in a sealed environment.

    By allowing your buffer to be extracted from the bottle using a luer lock syringe (not supplied), you benefit because the UV lamp can remain fixed to the bottle and solvent extracted as required, thus preventing contamination.

    In addition, it means that the buffer you use is identical to mobile phase component.

    Suits Solaris[PRO] UV Sterilisation Device – SOL-4668

  • £85.00
    SOL-4669

    Solaris[PRO] Universal Power Supply

    Power supply compatible with all worldwide power outlets including EU and UK.

    Suits Solaris:

    [PRO] UV Sterilisation Device (for 2-5 litre bottles with a GL-45 thread) – SOL-4668

    [PRO] UV Sterilisation Device (for 1 litre bottles with a GL-45 thread) – SOL-4802

  • £490.00
    SOL-4802

    Solaris[PRO] UV Sterilisation Device (1 litre)

    Protects your HPLC

    HPLC Instrumentation are easily adversely affected by bacteria, fungi and algae. By removing the threat of contaminated buffer sitting in-line, the SOLARIS[PRO] keeps your system well conditioned, thus avoiding expensive downtime and engineer call-outs.

    Toxic chemicals no longer required

    SOLARIS[PRO] supersedes the requirement for algae inhibitors, such as Sodium Azide, which affect chromatography.

    Sealed environment

    SOLARIS[PRO] sterilises the solvent after the bottle is filled. By utilising a 0.2 μm air intake filter, biological pathogens cannot form. In addition, contamination with particles from the laboratory environment (e.g. dust) is also prevented.

    Savings: Time and cost

    Solaris looks after itself – by having the lamp continuously switched on, man hours are considerably reduced and process efficiency maximised; no wasted solvent, no solvent disposal, no down time while new buffer is created, no associated buffer / preservative costs.

    Easy to handle

    • The system comes ready to use and can be mounted on all 1 Litre solvent bottle with a GL-45 thread.
    • Easy to install and to replace.
    • Cleaning: Simply rinse with deionised water.

    * Important note – power supply sold separately – buy here

  • £490.00
    SOL-4668

    Solaris[PRO] UV Sterilisation Device (2-5 litre)

    Protects your HPLC

    HPLC Instrumentation are easily adversely affected by bacteria, fungi and algae. By removing the threat of contaminated buffer sitting in-line, the SOLARIS[PRO] keeps your system well conditioned, thus avoiding expensive downtime and engineer call-outs.

    Toxic chemicals no longer required

    SOLARIS[PRO] supersedes the requirement for algae inhibitors, such as Sodium Azide, which affect chromatography.

    Sealed environment

    SOLARIS[PRO] sterilises the solvent after the bottle is filled. By utilising a 0.2 μm air intake filter, biological pathogens cannot form. In addition, contamination with particles from the laboratory environment (e.g. dust) is also prevented.

    Savings: Time and cost

    Solaris looks after itself – by having the lamp continuously switched on, man hours are considerably reduced and process efficiency maximised; no wasted solvent, no solvent disposal, no down time while new buffer is created, no associated buffer / preservative costs.

    Easy to handle

    • The system comes ready to use and can be mounted on all 2 litre -5 litre solvent bottles with a GL-45 thread.
    • Easy to install and to replace.
    • Cleaning: Simply rinse with deionised water.

    * Important note – power supply sold separately – buy here

  • £11.00
    A290012

    Spare 1/16

    Spare 1/16″ Cutting Wheel for Stainless Steel Tubing Cutter for 1/16″ Tube (part number A290011)

  • £8.00
    A200010

    Stainless Steel Tubing 1/16″ OD, 0.010″ ID

    For use with chromatography systems.

    • Priced by the metre*
    • 1/16″ OD
    • Tolerance (inches): ±0.0010
    • Made from 316-type stainless steel as fitted by Original Equipment Manufacturers (OEMs)
    • 0.010″/0.254mm ID
    • High quality chromatographic grade seamless drawn tubing
    • The use of 316 type offers superior chloride ion resistance
    • Rated for use between -53 and +280 degrees centigrade
    • High tolerance inside and outside diameters ensures trouble free use
  • £8.00
    A200011

    Stainless Steel Tubing 1/16″ OD, 0.020″ ID

    For use with chromatography systems.

    • Priced by the metre*
    • 1/16″ OD
    • Tolerance (inches): ±0.0010
    • Made from 316-type stainless steel as fitted by Original Equipment Manufacturers (OEMs)
    • 0.020″/0.508mm ID
    • High quality chromatographic grade seamless drawn tubing
    • The use of 316 type offers superior chloride ion resistance
    • Rated for use between -53 and +280 degrees centigrade
    • High tolerance inside and outside diameters ensures trouble free use
  • £8.00
    A200012

    Stainless Steel Tubing 1/16″ OD, 0.030″ ID

    For use with chromatography systems.

    • Priced by the metre*
    • 1/16″ OD
    • Tolerance (inches): ±0.0010
    • Made from 316-type stainless steel as fitted by Original Equipment Manufacturers (OEMs)
    • 0.030″/0.762mm ID
    • High quality chromatographic grade seamless drawn tubing
    • The use of 316 type offers superior chloride ion resistance
    • Rated for use between -53 and +280 degrees centigrade
    • High tolerance inside and outside diameters ensures trouble free use
  • £8.00
    A200013

    Stainless Steel Tubing 1/16″ OD, 0.040″ ID

    For use with chromatography systems.

    • Priced by the metre*
    • 1/16″ OD
    • Tolerance (inches): ±0.0010
    • Made from 316-type stainless steel as fitted by Original Equipment Manufacturers (OEMs)
    • 0.040″/1.016mm ID
    • High quality chromatographic grade seamless drawn tubing
    • The use of 316 type offers superior chloride ion resistance
    • Rated for use between -53 and +280 degrees centigrade
    • High tolerance inside and outside diameters ensures trouble free use
  • £109.00
    A290011

    Stainless Steel Tubing Cutter for 1/16

    Stainless Steel Tubing Cutter for 1/16″ Tube

  • £3.00
    A110011

    Stainless Steel Waters style Compression Screw (for 1/16

    Stainless Steel Waters style Compression Screw (for 1/16″ OD Tubing).

    Precision machined from high quality type 316 stainless steel to ensure leak tight connections at system pressures up to 6000 psi.

  • £2.00
    A110012

    Stainless Steel Waters style Ferrule for 1/16″ O.D. Tu...

    Stainless Steel Waters style ferrule (for 1/16″ OD tubing).

    Precision machined from high quality type 316 stainless steel to ensure leak tight connections at system pressures up to 6000 psi.

  • £140.00
    A403014

    Stator Face Assembly for Agilent G1313A / G1329A

    Stator face assembly for Agilent autosamplers (1100 / 1200 / 1260 / G1313A & G1329A).