  • £128.00
    HA-81026

    100µL, Model 1710 DX, Hamilton Syringe,Diluter with Stop

    Volume: 100 µL
    Syringe Type: Gastight
    Syringe Series: 1700
    Termination: Diluter PTFE Luer Lock (D)
    Plunger Style: Instrument Plunger Stop (X)
    Needle: No Needle Available
    Gauge: No Needle Included
    Point Style: No Needle Included
    Autoclavable: Yes
    Gas Sterilizable: Yes
    Maximum Pressure: 1000 psig (68.9 bar)
    Maximum Temperature: 115°C / 239°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: N/A
    Barrel Inner Diameter: 0.057 inches (1.46 mm)
    Barrel Outer Diameter: 0.305 inches (7.75 mm)
    Fluid Path: Borosilicate glass, PTFE
    Length: No Needle Included

  • £177.00
    HA-81326

    1mL, Model 1001 DX, Hamilton Syringe, Diluter with Stop

    Volume: 1 mL
    Syringe Type: Gastight
    Syringe Series: 1000
    Termination: Diluter PTFE Luer Lock (D)
    Plunger Style: Instrument Plunger Stop (X)
    Needle: No Needle Available
    Gauge: No Needle Included
    Point Style: No Needle Included
    Autoclavable: No
    Gas Sterilizable: Yes
    Maximum Pressure: 200 psig (13.8 bar)
    Maximum Temperature: 115°C / 239°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: N/A
    Barrel Inner Diameter: 0.181 inches (4.61 mm)
    Barrel Outer Diameter: 0.355 inches (9.02 mm)
    Fluid Path: Borosilicate glass, PTFE
    Length: No Needle Included

  • £128.00
    HA-81126

    250µL, Model 1725 DX, Hamilton Diluter Syringe with Stop

    Volume: 250 µL
    Syringe Type: Gastight
    Syringe Series: 1700
    Termination: Diluter PTFE Luer Lock (D)
    Plunger Style: Instrument Plunger Stop (X)
    Needle: No Needle Available
    Gauge: No Needle Included
    Point Style: No Needle Included
    Autoclavable: Yes
    Gas Sterilizable: Yes
    Maximum Pressure: 500 psig (34.5 bar)
    Maximum Temperature: 115°C / 239°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: N/A
    Barrel Inner Diameter: 0.091 inches (2.30 mm)
    Barrel Outer Diameter: 0.305 inches (7.75 mm)
    Fluid Path: Borosilicate glass, PTFE
    Length: No Needle Included

  • £142.00
    HA-80226

    25µL, Model 1702 DX, Hamilton Diluter Syringe with Stop

    Volume: 25 µL
    Syringe Type: Gastight
    Syringe Series: 1700
    Termination: Diluter PTFE Luer Lock (D)
    Plunger Style: Instrument Plunger Stop (X)
    Needle: No Needle Available
    Gauge: No Needle Included
    Point Style: No Needle Included
    Autoclavable: Yes
    Gas Sterilizable: Yes
    Maximum Pressure: 1000 psig (68.9 bar)
    Maximum Temperature: 115°C / 239°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: N/A
    Barrel Inner Diameter: 0.029 inches (0.729 mm)
    Barrel Outer Diameter: 0.305 inches (7.75 mm)
    Fluid Path: Borosilicate glass, PTFE
    Length: No Needle Included

  • £131.00
    HA-81226

    500µL, Model 1750 DX Hamilton Diluter Syringe with Stop

    Volume 500 µL
    Syringe Type Gastight
    Syringe Series 1700
    Termination Diluter PTFE Luer Lock (D)
    Plunger Style Instrument Plunger Stop (X)
    Needle No Needle Available
    Gauge No Needle Included
    Point Style No Needle Included
    Autoclavable Yes
    Gas Sterilizable Yes
    Maximum Pressure 700 psig (48.3 bar)
    Maximum Temperature 115°C / 239°F
    Minimum Temperature 10°C / 50°F
    Sales Quantity 1 syringe per pack
    Std. Needle Dead Volume N/A
    Barrel Inner Diameter 0.128 inches (3.26 mm)
    Barrel Outer Diameter 0.305 inches (7.75 mm)
    Fluid Path Borosilicate glass, PTFE
    Length No Needle Included

  • £142.00
    HA-80926

    50µL, Model 1705 DX, Hamilton Diluter Syringe with Stop

    Volume: 50 µL
    Syringe Type: Gastight
    Syringe Series: 1700
    Termination: Diluter PTFE Luer Lock (D)
    Plunger Style: Instrument Plunger Stop (X)
    Needle: No Needle Available
    Gauge: No Needle Included
    Point Style: No Needle Included
    Autoclavable: Yes
    Gas Sterilizable: Yes
    Maximum Pressure: 1000 psig (68.9 bar)
    Maximum Temperature: 115°C / 239°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: N/A
    Barrel Inner Diameter: 0.041 inches (1.03 mm)
    Barrel Outer Diameter: 0.305 inches (7.75 mm)
    Fluid Path: Borosilicate glass, PTFE
    Length: No Needle Included