Showing 1–20 of 125 results

  • £245.00
    HA-86257

    0.5µL, Model 7000.5 KH, Hamilton Syringe (Knurled Hub Needl...

    Volume: 0.5 µL
    Syringe Type: Microliter
    Syringe Series: 7000
    Termination: Knurled Hub (KH)
    Needle: KH
    Gauge: 32 gauge
    Point Style: 3
    Autoclavable: Yes
    Gas Sterilizable: Yes
    Maximum Pressure: 6000 psig (413.7 bar)
    Maximum Temperature: 115°C / 239°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: 0 µL
    Needle Inner Diameter: 0.0041 inches (0.104 mm)
    Needle Outer Diameter: 0.009 inches (0.235 mm)
    Barrel Inner Diameter: 0.0041 inches (0.104 mm)
    Barrel Outer Diameter: 0.308 inches (7.82 mm)
    Fluid Path: SST, tungsten
    Length: 3.94 inch (100 mm)

  • £98.00
    HA-86259

    0.5µL, Model 7000.5 KH, Hamilton Syringe (Knurled Hub Needl...

    Volume: 0.5 µL
    Syringe Type: Microliter
    Syringe Series: 7000
    Termination: Knurled Hub (KH)
    Needle: KH
    Gauge: 25 gauge
    Point Style: 2
    Autoclavable: Yes
    Gas Sterilizable: Yes
    Maximum Pressure: 6000 psig (413.7 bar)
    Maximum Temperature: 115°C / 239°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: 0 µL
    Needle Inner Diameter: 0.0041 inches (0.104 mm)
    Needle Outer Diameter: 0.020 inches (0.515 mm)
    Barrel Inner Diameter: 0.0041 inches (0.104 mm)
    Barrel Outer Diameter: 0.308 inches (7.82 mm)
    Fluid Path: SST, tungsten
    Length: 2.75 inch (69.9 mm)

  • £98.00
    HA-86250

    0.5µL, Model 7000.5 KH, Hamilton Syringe (Knurled Hub Needl...

    Volume: 0.5 µL
    Syringe Type: Microliter
    Syringe Series : 7000
    Termination: Knurled Hub (KH)
    Needle: KH
    Gauge: 25 gauge
    Point Style: 3
    Autoclavable: Yes
    Gas Sterilizable: Yes
    Maximum Pressure: 6000 psig (413.7 bar)
    Maximum Temperature: 115°C / 239°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: 0 µL
    Needle Inner Diameter: 0.0041 inches (0.104 mm)
    Needle Outer Diameter : 0.020 inches (0.515 mm)
    Barrel Inner Diameter: 0.0041 inches (0.104 mm)
    Barrel Outer Diameter: 0.308 inches (7.82 mm)
    Fluid Path: SST, tungsten
    Length: 2.75 inch (69.9 mm)

  • £161.00
    HA-86274

    0.5µL, Model 7000.5 KH, Hamilton Syringe for Agilent AS (Kn...

    Volume: 0.5 µL
    Syringe Type: Microliter
    Syringe Series: 7000
    Termination: Knurled Hub (KH)
    Needle: KH
    Gauge: 26 gauge
    Point Style: AS
    Autoclavable: Yes
    Gas Sterilizable: Yes
    Maximum Pressure: 6000 psig (413.7 bar)
    Maximum Temperature: 115°C / 239°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: 0 µL
    Needle Inner Diameter: 0.005 inches (0.13 mm)
    Needle Outer Diameter: 0.019 inches (0.483 mm)
    Barrel Inner Diameter: 0.049 inches (1.24 mm)
    Barrel Outer Diameter: 0.260 inches (6.60 mm)
    Fluid Path: SST, borosilicate glass
    Length: 1.71 inch (43.4 mm)

  • £161.00
    HA-86276

    0.5µL, Model 7000.5 KH, Hamilton Syringe for Agilent AS (Kn...

    Volume: 0.5 µL
    Syringe Type: Microliter
    Syringe Series: 7000
    Termination: Knurled Hub (KH)
    Needle: KH
    Gauge: 23 gauge
    Point Style: AS
    Autoclavable: Yes
    Gas Sterilizable: Yes
    Maximum Pressure: 6000 psig (413.7 bar)
    Maximum Temperature: 115°C / 239°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: 0 µL
    Needle Inner Diameter: 0.010 inches (0.25 mm)
    Needle Outer Diameter: 0.025 inches (0.64 mm)
    Barrel Inner Diameter: 0.049 inches (1.24 mm)
    Barrel Outer Diameter: 0.260 inches (6.60 mm)
    Fluid Path: SST, borosilicate glass
    Length: 1.71 inch (43.4 mm)

  • £123.00
    HA-203185

    1.2µL, Model 7701.2 KH, Hamilton Syringe For CTC Combi PAL ...

    Volume: 1.2 µL
    Syringe Type: Microliter
    Syringe Series: 7000
    Termination: Knurled Hub (KH)
    Needle: Small RN
    Gauge: 26 gauge
    Point Style: AS
    Autoclavable: No
    Gas Sterilizable: Yes
    Maximum Pressure: 6000 psig (413.7 bar)
    Maximum Temperature: 50°C / 122°F
    Minimum Temperature: 20°C / 68°F
    Sales Quantity : 1 syringe per pack
    Std. Needle Dead Volume: 0 µL
    Needle Inner Diameter: 0.005 inches (0.13 mm)
    Needle Outer Diameter: 0.0187 inches (0.47 mm)
    Fluid Path : SST, borosilicate glass
    Length: 2 inch (51 mm)

  • £114.00
    HA-80660

    100µL, Model 710 CA, Hamilton Syringes (Cemented Needle), 2...

    Volume: 100 µL
    Syringe Type: Microliter
    Syringe Series: 700
    Termination: Special
    Needle: Cemented Needle
    Gauge: 24 gauge
    Point Style: 3
    Autoclavable: No
    Gas Sterilizable: Yes
    Maximum Pressure: 2000 psig (137.9 bar)
    Maximum Temperature: 50°C / 122°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: 3.86 µL
    Needle Inner Diameter: 0.0122 inches (0.31 mm)
    Needle Outer Diameter: 0.0224 inches (0.57 mm)
    Barrel Inner Diameter: 0.061 inches (1.46 mm)
    Barrel Outer Diameter: 0.305 inches (7.75 mm)
    Fluid Path: SST, borosilicate glass
    Length: 2 inch (51 mm)

  • £74.00
    HA-80601

    100µL, Model 710 LT, Hamilton Syringe, Luer Tip (No needle)...

    Volume: 100 µL
    Syringe Type: Microliter
    Syringe Series : 700
    Termination: Luer Tip (LT)
    Needle: Kel-F Hub
    Gauge: No Needle Included
    Point Style: No Needle Included
    Autoclavable: Yes to 115°C
    Gas Sterilizable: Yes
    Maximum Pressure: 2000 psig (137.9 bar)
    Maximum Temperature: 115°C / 239°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: N/A
    Barrel Inner Diameter: 0.061 inches (1.46 mm)
    Barrel Outer Diameter: 0.305 inches (7.75 mm)
    Fluid Path: SST, borosilicate glass
    Length: No Needle Included

  • £56.00
    HA-80600

    100µL, Model 710 N, Hamilton Syringe (Cemented Needle), 22s...

    Volume: 100 µL
    Syringe Type: Microliter
    Syringe Series: 700
    Termination: Cemented Needle (N)
    Needle: Cemented Needle
    Gauge: 22s gauge
    Point Style: 2
    Autoclavable: No
    Gas Sterilizable: Yes
    Maximum Pressure: 2000 psig (137.9 bar)
    Maximum Temperature: 50°C / 122°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: 1.13 µL
    Needle Inner Diameter: 0.0059 inches (0.15 mm)
    Needle Outer Diameter: 0.0283 inches (0.72 mm)
    Barrel Inner Diameter: 0.061 inches (1.46 mm)
    Barrel Outer Diameter: 0.305 inches (7.75 mm)
    Fluid Path: SST, borosilicate glass
    Length: 2 inch (51 mm)

  • £56.00
    HA-80665

    100µL, Model 710 N, Hamilton Syringe (Cemented Needle), 22s...

    Volume: 100 µL
    Syringe Type: Microliter
    Syringe Series: 700
    Termination: Cemented Needle (N)
    Needle: Cemented Needle
    Gauge: 22s gauge
    Point Style: 3
    Autoclavable: No
    Gas Sterilizable: Yes
    Maximum Pressure: 2000 psig (137.9 bar)
    Maximum Temperature: 50°C / 122°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: 1.13 µL
    Needle Inner Diameter: 0.0059 inches (0.15 mm)
    Needle Outer Diameter: 0.0283 inches (0.72 mm)
    Barrel Inner Diameter: 0.061 inches (1.46 mm)
    Barrel Outer Diameter: 0.305 inches (7.75 mm)
    Fluid Path: SST, borosilicate glass
    Length: 2 inch (51 mm)

  • £61.00
    HA-763801

    100µL, Model 710 RN, Hamilton Syringe (No needle)

    Volume: 100 µL
    Syringe Type: Microliter
    Syringe Series: 700
    Termination: Removable Needle (RN)
    Needle: Small RN
    Gauge: No Needle Included
    Point Style: No Needle Included
    Autoclavable: Yes
    Gas Sterilizable: Yes
    Maximum Pressure: 2000 psig (137.9 bar)
    Maximum Temperature: 115°C / 239°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: N/A
    Barrel Inner Diameter: 0.014 inches (0.343 mm)
    Barrel Outer Diameter: 0.260 inches (6.60 mm)
    Fluid Path: SST, borosilicate glass
    Length: No Needle Included

  • £65.00
    HA-80630

    100µL, Model 710 RN,Hamilton Syringe (Small Removable Needl...

    Volume: 100 µL
    Syringe Type: Microliter
    Syringe Series: 700
    Termination: Removable Needle (RN)
    Needle: Small RN
    Gauge: 22s gauge
    Point Style: 2
    Autoclavable: Yes
    Gas Sterilizable: Yes
    Maximum Pressure: 2000 psig (137.9 bar)
    Maximum Temperature: 50°C / 122°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: 1.13 µL
    Needle Inner Diameter: 0.0059 inches (0.15 mm)
    Needle Outer Diameter: 0.0283 inches (0.72 mm)
    Barrel Inner Diameter: 0.061 inches (1.46 mm)
    Barrel Outer Diameter: 0.305 inches (7.75 mm)
    Fluid Path: SST, borosilicate glass
    Length: 2 inch (51 mm)

  • £92.00
    HA-80608

    100µL, Model 710 SN, Hamilton Syringe (Cemented Needle), Cu...

    Volume: 100 µL
    Syringe Type: Microliter
    Syringe Series: 700
    Termination: Cemented Needle Special (SN)
    Needle: Cemented Needle
    Autoclavable: No
    Gas Sterilizable: Yes
    Maximum Pressure: 2000 psig (137.9 bar)
    Maximum Temperature: 50°C / 122°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: N/A
    Barrel Inner Diameter: 0.061 inches (1.46 mm)
    Barrel Outer Diameter: 0.305 inches (7.75 mm)
    Fluid Path: SST, borosilicate glass

  • £101.00
    HA-84858

    100µL, Model 810 N, Hamilton Syringe (Cemented Needle) 22s ...

    Volume: 100 µL
    Syringe Type: Microliter
    Syringe Series: 800
    Termination: Cemented Needle (N)
    Needle: Cemented Needle
    Gauge: 22s gauge
    Point Style: 2
    Autoclavable: No
    Gas Sterilizable: Yes
    Maximum Pressure: 2000 psig (137.9 bar)
    Maximum Temperature: 50°C / 122°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: 1.13 µL
    Needle Inner Diameter: 0.0059 inches (0.15 mm)
    Needle Outer Diameter: 0.0283 inches (0.72 mm)
    Barrel Inner Diameter: 0.061 inches (1.46 mm)
    Barrel Outer Diameter: 0.305 inches (7.75 mm)
    Fluid Path: SST, borosilicate glass
    Length: 2 inch (51 mm)

  • £102.00
    HA-764501

    100µL, Model 810 RN, Hamilton Syringe (No needle)

    Volume: 100 µL
    Syringe Type: Microliter
    Syringe Series: 800
    Termination: Removable Needle (RN)
    Needle: Small RN
    Gauge: No Needle Included
    Point Style: No Needle Included
    Autoclavable: Yes
    Gas Sterilizable : Yes
    Maximum Pressure : 2000 psig (137.9 bar)
    Maximum Temperature: 115°C / 239°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: N/A
    Barrel Inner Diameter: 0.014 inches (0.343 mm)
    Barrel Outer Diameter: 0.260 inches (6.60 mm)
    Fluid Path: SST, borosilicate glass
    Length: No Needle Included

  • £106.00
    HA-84859

    100µL, Model 810 RN, Hamilton Syringe (Small Removable Need...

    Volume: 100 µL
    Syringe Type: Microliter
    Syringe Series: 800
    Termination: Removable Needle (RN)
    Needle: Small RN
    Gauge: 22s gauge
    Point Style: 2
    Autoclavable: Yes
    Gas Sterilizable: Yes
    Maximum Pressure: 2000 psig (137.9 bar)
    Maximum Temperature: 115°C / 239°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: 1.13 µL
    Needle Inner Diameter: 0.0059 inches (0.15 mm)
    Needle Outer Diameter: 0.0283 inches (0.72 mm)
    Barrel Inner Diameter: 0.061 inches (1.46 mm)
    Barrel Outer Diameter: 0.305 inches (7.75 mm)
    Fluid Path: SST, borosilicate glass
    Length: 2 inch (51 mm)

  • £119.00
    HA-84818

    100µL, Model 810 RN, Hamilton Syringe for Waters U6K SYR, (...

    Volume: 100 µL
    Syringe Type: Microliter
    Syringe Series: 800
    Termination: Removable Needle (RN)
    Needle: Small RN
    Gauge: 25s gauge
    Point Style: 3
    Autoclavable: Yes
    Gas Sterilizable: Yes
    Maximum Pressure: 2000 psig (137.9 bar)
    Maximum Temperature: 115°C / 239°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: 0.91 µL
    Needle Inner Diameter: 0.007 Inches (0.18 mm)
    Needle Outer Diameter: 0.02 inches (0.508 mm)
    Barrel Inner Diameter: 0.061 inches (1.46 mm)
    Barrel Outer Diameter: 0.305 inches (7.75 mm)
    Fluid Path: SST, borosilicate glass
    Length: 1.97 inch (50 mm)

  • £58.00
    HA-80301

    10µL, Model 701 LT, Hamilton Syringe, Luer Tip (No needle)

    Volume: 10 µL
    Syringe Type: Microliter
    Syringe Series: 700
    Termination: Luer Tip (LT)
    Needle: Kel-F Hub
    Gauge: No Needle Included
    Point Style: No Needle Included
    Autoclavable: Yes to 115°C
    Gas Sterilizable: Yes
    Maximum Pressure: 2000 psig (137.9 bar)
    Maximum Temperature: 115°C / 239°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: N/A
    Barrel Inner Diameter: 0.019 inches (0.485 mm)
    Barrel Outer Diameter: 0.260 inches (6.60 mm)
    Fluid Path: SST, borosilicate glass
    Length: No Needle Included

  • £52.00
    HA-80384

    10µL, Model 701 N, Hamilton Syringe (76mm Cemented Needle),...

    Volume: 10 µL
    Syringe Type: Microliter
    Syringe Series: 700
    Termination: Cemented Needle (N)
    Needle: Cemented Needle
    Gauge: 26s gauge
    Point Style: 2
    Autoclavable: No
    Gas Sterilizable: Yes
    Maximum Pressure: 2000 psig (137.9 bar)
    Maximum Temperature: 50°C / 122°F
    Minimum Temperature: 10°C / 50°F
    Sales Quantity: 1 syringe per pack
    Std. Needle Dead Volume: 0.97 µL
    Needle Inner Diameter : 0.005 inches (0.13 mm)
    Needle Outer Diameter: 0.0187 inches (0.47 mm)
    Barrel Inner Diameter : 0.019 inches (0.485 mm)
    Barrel Outer Diameter: 0.260 inches (6.60 mm)
    Fluid Path: SST, borosilicate glass
    Length: 3 inch (76.2 mm)

  • £146.00
    HA-80366

    10µL, Model 701 N, Hamilton Syringe (Cemented Needle) Bevel...

    Volume: 10 µL
    Syringe Type: Microliter
    Syringe Series: 700
    Termination: Cemented Needle (N)
    Needle: Cemented Needle
    Gauge: 26s gauge
    Point Style: 2
    Autoclavable: No
    Gas Sterilizable: Yes
    Maximum Pressure: 2000 psig (137.9 bar)
    Maximum Temperature: 50°C / 122°F
    Minimum Temperature : 10°C / 50°F
    Sales Quantity: 6 syringe per pack
    Std. Needle Dead Volume: 0.64 µL
    Needle Inner Diameter: 0.005 inches (0.13 mm)
    Needle Outer Diameter: 0.0187 inches (0.47 mm)
    Barrel Inner Diameter: 0.019 inches (0.485 mm)
    Barrel Outer Diameter: 0.260 inches (6.60 mm)
    Fluid Path: SST, borosilicate glass
    Length: 2 inch (51 mm)