GC Autosampler Syringes
|
All
needles are 42mm long with a cone point. All syringes,
needles and plungers are supplied in packs of one
unless otherwise noted. |
| |
Syringes |
Needles |
|
Volume |
Needle
Gauge
(ODmm) |
Syringe
Code |
Syringe Part No
|
Spare Needle Part No
|
Needle
Pack Size |
Spare
Plunger Part No |
Plunger
Pack Size |
|
|
Agilent 7670 - Removable Needle |
| 1µL |
23(0.63) |
1BR-F5 |
|
|
1** |
- |
- |
| |
|
|
|
|
|
|
|
|
Agilent 7673, 7683 & 68560 ALS- Fixed Tapered
Needle |
| 5µL |
23-26s
(0.63/0.47) |
5F-HP-0.63/0.47C |
|
- |
- |
- |
- |
| 10µL |
23-26s
(0.63/0.47) |
10F-HP-0.63/0.47C |
|
- |
- |
- |
- |
| 10µL
Gas Tight |
23-26s
(0.63/0.47) |
10F-HP-GT-0.63/0.47C |
|
- |
- |
- |
- |
| 25µL
Gas Tight |
23-26s
(0.63/0.47) |
25F-HP-GT-0.63/0.47C |
|
- |
- |
|
1 |
| 50µL
Gas Tight |
23-26s
(0.63/0.47) |
50F-HP-GT-0.63/0.47C |
|
- |
- |
|
1 |
| 100µL
Gas Tight |
23-26s
(0.63/0.47) |
100F-HP-GT-0.63/0.47C |
|
- |
- |
|
1 |
 |
| Fixed
Straight Needle |
| 5µL |
26
(0.47) |
5F-HP-0.47C |
|
- |
- |
- |
- |
| 5µL
(M) |
23
(0.63) |
5F-HP-0.63C |
|
- |
- |
- |
- |
| 10µL |
26
(0.47) |
10F-HP-0.47C |
|
- |
- |
- |
- |
| 10µL
(M) |
23
(0.63) |
10F-HP-0.63C |
|
- |
- |
- |
- |
| 10µL
(M) Gas Tight |
23
(0.63) |
10F-HP-GT-0.63C |
|
- |
- |
|
2 |
 |
| Fixed
Needle - SuperFlex Plunger |
| 10µL |
26
(0.47) |
10FX-HP-0.47 |
|
- |
- |
- |
- |
| 10µL
(M) |
23
(0.63) |
10FX-HP-0.63 |
|
- |
- |
- |
- |
 |
| Removable
Tapered Needle |
| 0.5µL |
23-26s
(0.63/0.47) |
0.5BR-HP-0.63/0.47C |
|
|
1** |
- |
- |
| 5µL |
23-26s
(0.63/0.47) |
5R-HP-0.63/0.47C |
|
|
2 |
- |
- |
| 10µL |
23-26s
(0.63/0.47) |
10R-HP-0.63/0.47C |
|
|
2 |
- |
- |
| 10µL
(M) Gas Tight |
23-26s
(0.63/0.47) |
10R-HP-GT-0.63/0.47C |
|
|
2 |
|
2 |
 |
| Removable
Straight Needle |
| 0.5µL |
26
(0.47) |
0.5BR-HP-0.47C |
|
|
1** |
- |
- |
| 0.5µL
(M) |
23
(0.63) |
0.5BR-HP-0.63C |
|
|
1** |
- |
- |
| 1µL |
23
(0.63) |
1BR-HP-0.63C |
|
|
1** |
- |
- |
| 5µL |
26
(0.47) |
5BR-HP-0.47C |
|
|
2 |
- |
- |
| 5µL
(M) |
23
(0.63) |
5R-HP-0.63C |
|
|
2 |
- |
- |
| 10µL |
26
(0.47) |
10R-HP-0.47C |
|
|
2 |
- |
- |
| 10µL
(M) |
23
(0.63) |
10R-HP-0.63C |
|
|
2 |
- |
- |
| 10µL
Gas Tight |
26
(0.47) |
10R-HP-GT-0.47C |
|
|
2 |
|
2 |
| 10µL
(M) Gas Tight |
23
(0.63) |
10R-HP-GT-0.63C |
|
|
2 |
|
2 |
| 25µL |
23
(0.63) |
25R-HP-0.63C |
|
|
2 |
- |
- |
| 50µL
(M) |
23
(0.63) |
50R-HP-0.63C |
|
|
2 |
- |
- |
| 100µL
(M) |
23
(0.63) |
100R-HP-0.63C |
|
|
2 |
- |
- |
| 250µL(M)
|
23
(0.63) |
250R-HP-0.63C |
|
|
2 |
- |
- |
 |
| Wide
Bore Needle - for use with 10µL syringe only |
| |
23
(0.63) / 0.15 ID |
N10-HP-0.63(0.15)C |
- |
|
2 |
- |
- |
 |
| Removable
Needle - SuperFlex Plunger |
| 10µL |
26
(0.47) |
10RX-HP-0.47C |
|
|
2 |
- |
- |
| 10µL |
23
(0.63) |
10RX-HP-0.63C |
|
|
2 |
- |
- |
** Denotes spare needle and Plunger Kit (M)
Suitable for use with the Merlin Microseal Injector. |
|
|
| |
GC Autosampler Syringes
|
All
syringes, needles and plungers are supplied in packs
of one unless otherwise noted. |
| |
Syringes |
Needles |
|
Volume |
Needle
Gauge
(ODmm) |
Syringe
Code |
Syringe Part No
|
Spare Needle Part No
|
Needle
Pack Size |
Spare
Plunger Part No |
Plunger
Pack Size |
|
|
 |

AS100, AS2000 and AS8300
Removable Needle - 78mm long with a cone point style |
| 3µL |
26(0.47) |
3R-PS-0.47 |
|
|
2 |
- |
- |
| |
|
|
|
|
|
|
|
Autosystem
Fixed Needle - 70mm long with a cone point style |
| 5µL |
26
(0.47) |
5F-PE-0.47C |
|
- |
- |
- |
- |
| 5µL |
23
(0.63) |
5F-PE-0.63C |
|
- |
- |
- |
- |
| 5µL
Gas Tight |
26
(0.47) |
5F-PE-GT-0.47C |
|
- |
- |
|
2 |
| 5µL
Gas Tight |
23
(0.63) |
5F-PE-GT-0.63C |
|
- |
- |
|
2 |
| 50µL |
23
(0.63) |
50F-PE-0.63C |
|
- |
- |
|
1 |
| 100µL
Gas Tight |
23-26s
(0.63/0.47) |
100F-HP-GT-0.63/0.47C |
|
- |
- |
- |
- |
 |
| Removable
Needle |
| 0.5µL |
26
(0.47) |
0.5BR-PE-0.47C |
|
|
1** |
- |
- |
| 0.5µL |
23
(0.63) |
0.5BR-PE-0.63C |
|
|
1** |
- |
- |
** Denotes spare needle and Plunger Kit |
|
| |
GC Autosampler Syringes
|
All
syringes, needles and plungers are supplied in packs
of one unless otherwise noted. |
| |
Syringes |
Needles |
|
Volume |
Needle
Gauge
(ODmm) |
Syringe
Code |
Syringe Part No
|
Spare Needle Part No
|
Needle
Pack Size |
Spare
Plunger Part No |
Plunger
Pack Size |
|
|
 |

AOC9
Removable Needle - 50mm long with a cone point style |
| 0.5µL |
26(0.47) |
0.5BR-S(9)-5/0.47C |
|
|
1** |
- |
- |
| 10µL |
26(0.47) |
10R-S(9)-5/0.47 |
|
|
2 |
- |
- |

AOC14, AOC17 and AOC20
Fixed Needle - 42mm long with a cone point style |
| 5µL |
26(0.47) |
5F-S-0.47C |
|
- |
- |
- |
- |
| 5µL |
23(0.63) |
5F-S-0.63C |
|
- |
- |
- |
- |
| 250µL
Gas Tight |
23(0.63) |
250F-S-GT-0.63C |
|
- |
- |
|
1 |
| |
|
|
|
|
|
|
|
|
Removable Needle - 42mm long with a cone point
style |
| 0.5µL |
26
(0.47) |
0.5BR-S-0.47C |
|
|
1** |
-
|
- |
| 0.5µL |
23
(0.63) |
0.5BR-S-0.63C |
|
|
1** |
-
|
- |
| 10µL |
26
(0.47) |
10R-S-0.47C |
|
|
2 |
-
|
- |
| 10µL |
23
(0.63) |
10R-S-0.63C |
|
|
2 |
-
|
- |
| 10µL
Gas Tight |
23
(0.63) |
10R-S-GT-0.63C |
|
|
2 |
|
2 |
** Denotes spare needle and Plunger Kit |
|
| |
Thermo Electron GC Autosampler Syringes
|
All
syringes, needles and plungers are supplied in packs
of one unless otherwise noted. |
| |
| Model(s) |
Volume |
Length
mm |
Needle
Gauge
(ODmm) |
Tip
Style |
Syringe
Code |
Syringe Part No
|
Spare Needle Part No
|
Needle
Pack Size |
Spare
Plunger Part No |
Plunger
Pack Size |
|
|
|
|
 |

Fixed Needle |
| TriPlus |
5µL |
50 |
26(0.47) |
Cone |
5FX-5C |
|
- |
- |
- |
- |
| TriPlus,
AS2000 |
10µL |
80 |
23(0.63) |
Cone |
10F-C/T-8/0.63C |
|
- |
- |
-
|
- |
| TriPlus,
AS2000 |
10µL |
80 |
26(0.47) |
Cone |
10F-C/T-8/0.47C |
|
- |
- |
-
|
- |
| TriPlus,
AS2000, AS3000 & AS200/800 |
10µL |
50 |
25(0.50) |
Cone |
10F-C/T-5/0.50C |
|
- |
- |
-
|
- |
| TriPlus,
AS2000 |
10µL
Gas Tight |
50 |
23(0.63) |
Cone |
10F-C/T-GT-5/0.63C |
|
- |
- |
|
2 |
| TriPlus,
AS2000, AS3000 & AS200/800 |
10µL |
50 |
23(0.63) |
Cone |
10F-C/T-5/0.63C |
|
- |
- |
-
|
- |
| TriPlus,
AS2000, AS3000 & AS200/800 |
10µL |
50 |
26(0.47) |
Cone |
10F-C/T-5/0.47C |
|
- |
- |
-
|
- |

Removable Needle |
| TriPlus,
AS3000 |
0.5µL |
50 |
26(0.47) |
Cone |
0.5BNR-C/T-5/0.47C |
|
|
- |
-
|
- |
| TriPlus,
AS3000 |
0.5µL |
50 |
23(0.63) |
Cone |
0.5BNR-C/T-5/0-0.63C |
|
|
- |
-
|
- |
| TriPlus,
AS3000, AS2000 |
10µL |
50 |
26(0.47) |
Cone |
10R-C/T-5/0.47C |
|
|
2 |
- |
- |
| TriPlus,
AS2000, AS3000 & AS200/800 |
10µL |
50 |
23(0.63) |
Cone |
10R-C/T-5/0.63C |
|
|
2 |
- |
- |
| TriPlus,
AS2000, AS3000 & AS200/800 |
10µL |
80 |
26(0.47) |
Cone |
10R-C/T-8/0.47C |
|
|
3 |
- |
- |
|
| |
GC Autosampler Syringes
|
All
syringes, needles and plungers are supplied in packs
of one unless otherwise noted. |
| |
|
Volume |
Length
mm |
Needle
Gauge
(ODmm) |
Tip
Style |
Syringe
Code |
Syringe Part No
|
Spare Needle Part No
|
Needle
Pack Size |
Spare
Plunger Part No |
Plunger
Pack Size |
|
|
|
 |

Varian 8035, 8100 and 8200
Removable Needle |
| 1µL |
51 |
26(0.47) |
Cone |
1BR-VA8X |
|
|
1** |
-
|
- |
| 10µL
Gas Tight |
53 |
25(0.50) |
S/Hole |
10R-VA8X-II |
|
|
1 |
|
1 |

Fixed Needle |
| 10µL
Gas Tight |
53 |
25(0.5) |
S/Hole |
10F-VA8X-II |
|
- |
- |
|
1 |
| Needle
Alternatives for P/N 002924 |
| |
50 |
25(0.50) |
Bevel |
N10-VA8035-II |
-
|
|
2 |
-
|
- |
| |
105 |
- |
OC |
N10-VA8035-0.17-II |
- |
|
2 |
-
|
- |
| |
53 |
23(0.63) |
S/Hole |
N10-VA8X00H-0.63-II |
- |
|
2 |
-
|
- |
| |
53 |
25(0.5) |
S/Hole |
N10-VA800H-II(0.2) |
- |
|
1 |
-
|
- |
| 100µL |
53 |
25(0.5) |
S/Hole |
100R-VA8X |
|
|
1 |
|
1 |

Varian CP-8400/8410, CP-9010/9050 Fixed Needle |
| 10µL |
50 |
26(0.47) |
Bevel |
10F-VA8400-5/0.47 |
|
- |
- |
-
|
- |
| 10µL |
50 |
23(0.63) |
Cone |
10F-C/T-5/0-0.63C |
|
- |
- |
-
|
- |

Varian CP-8400/8410, CP-9010/9050 Removable Needle |
| 10µL |
50 |
26(0.47) |
Cone |
10R-C/T-5/0.47C |
|
|
2 |
- |
- |
*Not suitable for 8200 autosampler. **Denotes plunger
and needle kit. |
|
| |
CTC/Leap GC Autosampler Syringes
|
All
needles are 50mm long. All syringes, needles and plungers
are supplied in packs of one unless otherwise noted. |
| |
Syringes |
Needles |
|
Volume |
Needle
Gauge
(ODmm) |
Tip
Style |
Syringe
Code |
Syringe Part No
|
Spare Needle Part No
|
Needle
Pack Size |
Spare
Plunger Part No |
Plunger
Pack Size |
|
|
 |

Fixed Needle |
| 5µL |
26(0.47) |
Cone |
5F-C/T-5/0.47C |
|
- |
- |
-
|
- |
| 5µL |
23(0.63) |
Cone |
5F-C/T-5/0.63C |
|
- |
- |
-
|
- |
| 10µL |
26(0.47) |
Cone |
10F-C/T-5/0.47C |
|
- |
- |
-
|
- |
| 10µL |
23(0.63) |
Cone |
10F-C/T-5/0.63C |
|
- |
- |
-
|
- |
| 10µL |
26(0.47) |
Bevel |
10F-C/T-5/0.47BV |
|
- |
- |
-
|
1 |
| 10µL
Gas Tight |
23(0.63) |
Cone |
10F-C/T-GT-5/0.63C |
|
- |
- |
|
2 |
| 25µL |
26(0.47) |
Cone |
25F-C/T-5/0.47C |
|
- |
- |
-
|
- |
| 25µL
Gas Tight |
26(0.47) |
Cone |
25F-CTC-GT-5/0.47C |
|
- |
- |
|
1 |
| 25µL
Gas Tight |
23(0.63) |
Cone |
25F-C/T-GT-5/0.63C |
|
- |
- |
|
1 |
| 100µL
Gas Tight |
26(0.47) |
Cone |
100F-C/T-GT-5/0.47C |
|
- |
- |
|
1 |
| 100µL
Gas Tight |
23(0.63) |
Cone |
100F-C/T-GT-5/0.63C |
|
- |
- |
|
1 |
| 250µL
Gas Tight |
26(0.47) |
Cone |
250F-C/T-GT-5/0.47C |
|
- |
- |
|
1 |
| 500µL
Gas Tight |
26(0.47) |
Cone |
500F-C/T-GT-5/0.47C |
|
- |
- |
|
1 |

Removable Needle |
| 0.5µL |
26(0.47) |
Cone |
0.5BNR-C/T-5/0.47C |
|
|
1** |
-
|
- |
| 0.5µL |
23(0.63) |
Cone |
0.5BNR-C/T-5/0-0.63C |
|
|
1** |
-
|
- |
| 10µL |
26(0.47) |
Cone |
10R-C/T-5/0.47C |
|
|
2 |
- |
- |
| 10µL |
23(0.63) |
Cone |
10R-C/T-5/0.63C |
|
|
2 |
-
|
- |
| 10µL
Gas Tight |
26(0.47) |
Cone |
10R-C/T-GT-5/0-0.47C |
|
|
2 |
|
2 |
| 25µL
Gas Tight |
26(0.47) |
S/Hole |
25R-C/T-GT-5/0.47H |
|
|
2 |
|
1 |
| 100µL
Gas Tight |
26(0.47) |
Cone |
100R-C/T-GT-5/0.47C |
|
|
2 |
|
1 |
**Denotes spare Needle and Plunger kit. |
|
| |
| |
| |
| |
|
|
|
|
 |
|
|