ACQUITY CLASSIC BINARY BSM / SM / CM-A / CM-Aux / TUV / SO SYSTEM
Waters Binary UV UPLC For Sale
Ref: 108
Gallery
Download Classic Acquity OQ and Reproducibility data
The Acquity system comes complete with OQ Certification.
- The binary pump has been tested for faulty parts such as seals and check valves
- The detector has been tested for wavelength accuracy
- The sample manager has been tested for area of reproducibility
This Waters® ACQUITY UPLC® System provides an integrated configuration for solvent and XYZZ sample management designed for use with ACQUITY UPLC chemistries. Complete with an OQ certification – see photos.
Includes fully reconditioned and serviced:
- Waters Acquity Classic Binary Solvent Manager (BSM)
- Waters Acquity Classic Sample Manager (SM)
- Waters Acquity Classic UV Detector (TUV)
- Waters Acquity H-Class Column Manager (CM-A)
- Waters Acquity H-Class Auxiliary Column Manager (CM-Aux)
- Waters Acquity Classic Sample organiser (SO)
- Bottle Manager
Optional extras (enquire for price):
- Acquity PDA (Diode Array Detector)
- CH-30A Column Heater
We can supply software, PC printer and installation – please call +44(0)1227 265333 for a full quotation.
System Specification
Acoustic noise: <65 dBA
Operating temperature range: 4.0 to 40.0 °C (39.2 to 104.0 °F).
Operating humidity range: 20% to 50%, non-condensing.
Operating Voltage: 90 to 264 Vac
Frequency: 47 to 63 Hz.
External communications: Ethernet interfacing via RJ45 connection to host PC
Event inputs/outputs: Rear panel contact closure and/or TTL inputs/outputs.
BSM Specification
Number of solvents: Up to four: in any combination of two: A1 or A2 and B1 or B2.
Solvent storage: Solvents Tray accommodates up to four chromatographic solvents, two Sample Manager wash solvents and one Binary Solvent Manager seal wash solvent.
Solvent conditioning: Vacuum degassing (six-channel): one channel per solvent, and two channels for Sample Manager wash solvents.
Operating flow rate range: 0.010 to 2.000 mL/min, in 0.001 mL increments.
Compressibility compensation : Automatic and continuous.
SM Specification
Injection volume range: 0.1 to 50.0 µL, in 0.1 µL increments, partial or full loop mode. 10-µL loop is standard; 1, 2, 5, 20, and 50-µL loops also available.
Maximum sample capacity: 768 in two 384-well plates; expandable to up to 8,448 samples using Sample Organiser .
Number of sample injections: 1 to 99 injections per sample.
Injection volume range: 0.1 to 50.0 µL, in 0.1 µL increments, partial or full loop mode. 10-µL loop is standard; 1, 2, 5, 20, and 50-µL loops also available.
TUV Specification
Wavelength range 1: 190 to 700 nm
Wavelength accuracy: ±1 nm
Linearity range: Deviation at 2.5 AU ≤ 5%, propylparaben, at 257 nm
Baseline noise: 6 x 10-6 AU, at 230 nm, 10 mm shunt cell, 1.0 second filter time constant.
Drift : ≤ 5% x 10-4 AU/hour/°C, at 230nm
Sampling rate: Up to 80 points/s.
CM-A Specification
CM-A Column capacity: Two columns, as standard (maximum length of 150 mm with filter or guard column) or four columns (maximum length of 50 mm) can be supported with optional tubing kit, up to 4.6 mm internal diameter (I.D.).
CM-Aux Column capacity: Two columns (maximum length of 150 mm, with filter or guard column) .
Switching valves: Two nine-port, eight-position valves providing programmable, automatic, random access switching, waste and bypass positions for rapid solvent changeover
Column compartment temperature range: 4.0 to 90.0 °C, settable in 0.1 °C increments. Two independent heat/cool zones per module, up to six zones in stacked configuration.
Column compartment temperature accuracy: ±0.5 °C at sensor.
Column compartment temperature stability: ±0.3 °C at sensor.
Solvent conditioning: Active pre-heating as standard.
Column tracking: eCord™ Technology column information management tracks and archives column usage history.
2D support: Optional
CO Specification
Number of sample plates: Total of up to: 21 standard microtiter plates / 11 intermediate height plates / 7 deep-well (or 2-mL vial) plates / Combinations thereof.
CM-Aux Column capacity: Two columns (maximum length of 150 mm, with filter or guard column) .
Maximum sample capacity : Total of up to 8,448 samples: in 22 384-well plates, or seven 336 2-mL vials.
Temperature control: 4.0 to 40.0 °C, settable in 0.1 °C increments.
Plate exchange: <15 sec (retrieval and replace time)
Sample temperature control: At ambient temperature of 21 °C or lower, the sample organizer will maintain the temperature of the sample compartment down to 4 °C with a tolerance of -2/+6 °C, when configured with the maximum number of vials and/or plates; for ambient temperatures above 21 °C, there is a delta of 17 °C from actual ambient temperature.
Racks : 10 storage shelf assemblies supplied standard.
View Waters System Specification | View Waters TUV Specification