Gas or LiquidLiquid

GASTIGHT 1000, 1700 & 1800 Series

MICROLITER 600, 700, 800 and 900 Series

1000 Series

  • 1700 Series 10µL to 500µL

  • 1000 Series 1mL to 100mL

  • Also available: ground glass tip (luer tip, LT)
    or Teflon® luer lock (TLL) terminations

600 Series

  • 2.5µL and 5µL

  • Reinforced plungers prevent plunger bending

  • Rugged, durable and long lasting

1700 Series

  • 1700 Series 10µL to 500µL

  • 1000 Series 1mL to 100mL

  • Also available: ground glass tip (luer tip, LT)
    or Teflon® luer lock (TLL) terminations

700 Series

  • 5µL and 500µL

  • Economical: great for chromatography

  • Also available: ground glass tip (luer tip, LT)
    termination

1800 Series

  • 10µL to 250µL

  • Reinforced plunger prevents blow-out and plunger
    bending

  • Replaceable syringe barrels and plungers

800 Series

  • 5µL and 250µL

  • Reinforced plungers

  • Plunger stop prevents plunger blow-out

900 Series

  • 5µL and 10µL

  • Reinforced plungers

  • Perfect for students: rugged and durable

MODIFIED 7000 Series

  • 0.5µL and 5µL

  • Positive displacement syringe has a tungsten plunger
    wire that travels inside the needle

  • The needle essentially acts as the glass syringe
    barrel; no dead volume

  • Replaceable plunger wire and needle

What is your dispense or injection volume?

Dispensing Volume Table

Which termination works best for you?

LTN
Luer Tip Cemented Needle
Needles are cemented into the conical glass luer tip of the barrel at a point corresponding to the zero graduation mark.
N,NR
Cemented
Needles are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. NR stands for syringes with Rheodyne specified needles.
SN, LTSN
Special Needle, Luer Tip Special Needle
Hamilton offer customised syringes with special needles. State the following: needle length, guage, point style, and whether electro-tapered.
LT
Luer Tip
Ground glass syringe barrel with a male luer taper accepts most hyperdermic needles. Use Kel-F hub needle and connectors for a tight seal.
RN, RNR
Removable Needle, Removable Rheodyne Needle
Removable needles seat precisely to the zero mark of the syringe. Allows the use of different specification needles on the same syringe barrel. RNR stands for syringes with Rheodyne specified removable needles.
KH
Knurled Hub
Replaceable needle; knurled hub is used on 7000 series syringes exclusively. The attachment of a spacer enables repeatable depth injections.
SL
SampleLock
On/Off syringe valve with RN needle is cemented to a syringe barrel. Used for headspace, environmental sample collection and storage, pre-pressurisation of gaseous samples for GC analysis, and sample spiking.
TLL, TLLX
Teflon® Luer Lock
Male luer taper with nickel-plated brass hub accepts and locks in place luer hub needles and connectors. The X-style plunger stop incorporates a 6-32 UNC female thread on the end of the stop to allow attachment to drive arm mechanisms such as on the MICROLAB 500 series diluters/dispensers.
TLLXB
TLL with Stop & Backflushing
Used in drive arm mechanisms such as on MICROLAB 4000 or PSD2. Back-bushing syringes increase plunger tip life, maintain proper plunger alignment and reduce the particles generated by plunger to glass contact.
TLL-XL
60mm TLL Syringe
These 60mm stroke TLL-style syringes are compatible with many liquid handling instruments, including XL-3000 modular digital syringe pump, Tecan, Rosys, Cavro IQ series sample processors and OEM liquid handling applications.
TLL/TLLX
Short Stroke
These syringes are designed specifically for the PSD3 (half height syringe pump).
C/CX
Cheminert
1/4"-28 UNF, male fitting. Used in low volume applications where system dead volumes need to be minimised. The X-style plunger stop incorporates a 6-32 UNC female thread on the end of the stop to allow attachment to drive arm mechanisms, such as on the MICROLAB 500 series diluters/dispensers.
C-XP
30mm C Syringe

These 30mm stroke C-style syringes are compatible with many liquid handling instruments, including XL-3000 modular digital syringe pump, Tecan, Rosys, Cavro IQ series sample processors and OEM liquid handling applications.
DX
Dilutor
TLL, TEFLON Luer Lock, male fitting with M6 x 1 female, side port. The X-style plunger stop incorporates a 6-32 UNC female thread on the end of the stop to allow attachment to drive arm mechanism, such as on the MICROLAB 500 series diluters/dispensers.
AD
AccuDil®
M8 x 0.75, male fitting. Used with MICROLAB 1000 plus diluter/dispenser.
DAD
Diluter AccuDil®
M8 x 0.75 male fitting with M6 x 1 sideport. Used with MICROLAB 1000 plus diluter/dispenser.
Electro-taperedSome replacement needles can be specified as electro-tapered. Use this style for applications such as attaching PTFE tips, or for use on on-column GC injectors.

Which needle point style works best?

Hamilton Point Styles

Point Style AS: special conical style needle point designed to withstand the demands of multiple injections; exclusively used on autosampler syringes.

Point Style 2: 10 – 12° bevelled non-coring needle point recommended for septum penetration; only needle gauges 26s – 22 are recommended for optimum septum penetration.

Point Style 3: blunt needle point for use with HPLC injection valves and for sample pipetting.

Point Style 4: 10 – 12° bevelled needle point recommended for life science applications; special point styles such as 12°, and 45° are available on request.

Point Style 5: conical needle with side port for penetration of septa, thin-gauged vinyls and plastics without coring; minimizes septum damage.

Do you need a rugged syringe?

Syringe Guide – easily installed on a syringe to prevent the plunger from bending or from being pulled out.

Reproducibility (Chaney) Adapter – easily installed on a syringe for consistent, reproducible injections; also prevents plunger damage.

Reinforced Plungers – Series 600, 800, 900 and 1800 syringes offer an extended barrel which prevents bent plungers.