Showing 1–20 of 21 results
-
£725.00HA-86346
100mL, Model 1100 SL, Hamilton SampleLock Syringe (Large Rem...
Volume: 100 mL
Syringe Type: Gastight
Syringe Series: 1000
Termination: Sample Lock (SL)
Needle: Large RN
Gauge: 22 gauge
Point Style: 2
Autoclavable: No
Gas Sterilizable: Yes
Maximum Pressure: 100 psig (6.9 bar)
Maximum Temperature: 80°C / 176°F
Minimum Temperature: 10°C / 50°F
Sales Quantity: 1 syringe per pack
Std. Needle Dead Volume: 6.81 µL
Needle Inner Diameter: 0.0161 inches (0.41 mm)
Needle Outer Diameter : 0.0283 inches (0.72 mm)
Barrel Inner Diameter: 1.28 inches (32.6 mm)
Barrel Outer Diameter: 1.45 inches (36.9 mm)
Fluid Path: SST, borosilicate glass, PTFE
Length: 2 inch (51 mm) -
£406.00HA-86020
100mL, Model 1100 TLL, Hamilton Syringe (No needle) Teflon L...
Volume: 100 mL
Syringe Type: Gastight
Syringe Series: 1000
Termination: PTFE Luer Lock (TLL)
Needle: Metal (N) or Kel-F
Gauge: No Needle Included
Point Style: No Needle Included
Autoclavable: No
Gas Sterilizable: Yes
Maximum Pressure: 100 psig (6.9 bar)
Maximum Temperature: 80°C / 176°F
Minimum Temperature: 10°C / 50°F
Sales Quantity: 1 syringe per pack
Std. Needle Dead Volume: N/A
Barrel Inner Diameter: 1.28 inches (32.6 mm)
Barrel Outer Diameter: 1.45 inches (36.9 mm)
Fluid Path : Borosilicate glass, PTFE
Length: No Needle Included -
£95.00A403016
1200 SL PEEK Rotor Seal for Autosamplers | Like Agilent 0101...
PEEK rotor seal for use on Agilent 1200 SL autosamplers.
Designed to work with all 1200 series 600 bar systems (1200 SL G1329B, 1220 Infinity, 1260 Infinity), this alternative part represents a significant cost saving to the OEM.
Alternative to Agilent part no. 0101-1422.
-
£48.00SGE-001100
5µL SGE MicroVolume Syringe Fixed Needle – SuperFleX ...
Code: 5FX
OD (mm): 0.47
Needle Length (mm): 50
Tip Style: Bevel
Volume: 5µL
Gauge: 26 -
£2.95A400013
Cap for Agilent 1100 / 1200 Purge Valve Assembly
Cap for Agilent 1050, 1100 and 1200 quaternary, binary and isocratic pump purge valve (and outlet ball valve on binary) assembly.
-
£95.00A400025
Cartridge for Agilent 1100 Active Inlet Check Valves
Cartridge for Agilent 1100 active inlet check valves (isocratic G1310A, binary G1312A & quaternary pumps G1311A).
-
£17.00A400016
Frits for Agilent 1100 / 1200 Purge Valve Assembly. 5 Pack
Frits for Agilent 1050, 1100 and 1200 quaternary, binary and isocratic pump purge valve assembly.
-
£22.00A403011
Isolation Seal for Agilent G1313 / G1329
Isolation seal for Agilent 1100 and 1200 G1313 / G1329 autosamplers.
-
£50.00A403013
Needle Assembly for Agilent G1313 / G1329 Autosamplers
Needle assembly for Agilent 1100, 1200 and 1260 G1313 / G1329 autosamplers.
-
£125.00A403012
Needle Seat Assembly for Agilent G1313 / G1329 Autosamplers
Needle seat assembly for Agilent 1100, 1200 and 1260 G1313 / G1329 autosamplers.
-
£145.00A400015
Outlet Check Valve Assembly For Agilent Iso & Quat Pump...
Outlet check valve (outlet ball valve) assembly for Agilent isocratic & quaternary pumps.
-
£8.00A400014
PEEK Gold Seal for Agilent 1100/1200 Purge Valve Assembly
PEEK Gold Seal for Agilent 1100 and 1200 quaternary, binary and isocratic pump purge valve (and outlet ball valve on binary) assembly.
-
£26.00A400011
Plunger Seal for Agilent 1100 & 1200 Autosamplers &...
Piston seal for use on Agilent 1100 and 1200 quaternary, binary and isocratic pumps, and ALS autosamplers.
Suits kromega Piston/Plunger A400010 – see below.
-
£77.00A400010
Sapphire Plunger for Agilent 1100 & 1200 Autosamplers &...
Piston assembly for use on Agilent 1100 and 1200 Quarternary, Binary and Isocratic pumps and ALS.
-
£2.55A400017
Seal Wash Gasket for Agilent 1100/1200 Pump Head Assembly
ETFE Washer (seal wash option) for Agilent 1100 and 1200 quaternary, binary and isocratic pump head assembly.
-
£1,295.00A500100-2
THF 2 Channel Degasser, 480µL
THF resistant chambers (as standard), 480µL internal volume, 2 channel kromega Solvent Degasser.
- Communicates with 1100 and 1200 systems in exactly the same way that a G1322 / G1379 does
- THF resistant
- Long life – 5 years continuous run times
- Quicker vac down times
- 2 channels (independent chambers, so if one were to fail, can be economically repaired)
- Internal channel volume of only 480µL
- DuPont / Teflon AF membrane
- Eliminates baseline fluctuations due to the vacuum pump
- Closed loop vacuum control means constant vacuum (variable RPM)
- Advanced error & leak checking functions
- Short vacuum pull-down times, typically 3 mins
- Removes pre-bubbles formed by cavitation vs bubbles formed by off-the-floor eluent reservoirs
- Extremely quiet operational noise
- Wetted parts – PEEK & Teflon AF
- Integrates into any HPLC system
-
£1,495.00A500100-3
THF 3 Channel, 480µL Solvent Degasser
THF resistant chambers (as standard), 480µL internal volume, 3 channel kromega Solvent Degasser.
- Communicates with 1100 and 1200 systems in exactly the same way that a G1322 / G1379 does
- THF resistant
- Long life – 5 years continuous run times
- Quicker vac down times
- 3 channels (independent chambers, so if one were to fail, can be economically repaired)
- Internal channel volume of only 480µL
- DuPont / Teflon AF membrane
- Eliminates baseline fluctuations due to the vacuum pump
- Closed loop vacuum control means constant vacuum (variable RPM)
- Advanced error & leak checking functions
- Short vacuum pull-down times, typically 3 mins
- Removes pre-bubbles formed by cavitation vs bubbles formed by off-the-floor eluent reservoirs
- Extremely quiet operational noise
- Wetted parts – PEEK & Teflon AF
- Integrates into any HPLC system
-
£1,695.00A500100-4
THF 4 Channel, 480µL Solvent Degasser
THF resistant chambers (as standard), 480µL internal volume, 4 channel kromega Solvent Degasser.
- Communicates with 1100 and 1200 systems in exactly the same way that a G1322 / G1379 does
- THF resistant
- Long life – 5 years continuous run times
- Quicker vac down times
- 4 channels (independent chambers, so if one were to fail, can be economically repaired)
- Internal channel volume of only 480µL
- DuPont / Teflon AF membrane
- Eliminates baseline fluctuations due to the vacuum pump
- Closed loop vacuum control means constant vacuum (variable RPM)
- Advanced error & leak checking functions
- Short vacuum pull-down times, typically 3 mins
- Removes pre-bubbles formed by cavitation vs bubbles formed by off-the-floor eluent reservoirs
- Extremely quiet operational noise
- Wetted parts – PEEK & Teflon AF
- Integrates into any HPLC system
-
£49.50A403010
Vespel Rotor Seal for Agilent 1100 & 1200 Autosamplers
Vespel rotor seal for use on Agilent 1100 and 1200 ALS.
-
£36.00A400022
Wash Seal for Agilent 1100 & 1200 Pumps – Normal ...
Wash seal for Agilent 1100 & 1200 Pump head assemblies – Normal phase.